[source]

Entity xil_SystemMonitor

Resetstd_logicVPstd_logicVNstd_logicAlarm_UserTempstd_logicAlarm_OverTempstd_logicAlarmstd_logic

Block Diagram of xil_SystemMonitor

This module wraps a SYSMON or XADC to report if preconfigured temperature values are overrun. The XADC was formerly known as "System Monitor".

Temperature Curve

                |                      /-----\
Temp_ov   on=80 | - - - - - - /-------/       \
                |            /        |        \
Temp_ov  off=60 | - - - - - / - - - - | - - - - \----\
                |          /          |              |\
                |         /           |              | \
Temp_us   on=35 | -  /---/            |              |  \
Temp_us  off=30 | - / - -|- - - - - - |- - - - - - - |- -\------\
                |  /     |            |              |           \
----------------|--------|------------|--------------|-----------|--------
pwm =           |   min  |  medium    |   max        |   medium  |  min
Ports

Name

Type

Direction

Description

Reset

std_logic

in

Reset signal for the System Monitor control logic

Alarm_UserTemp

std_logic

out

Temperature-sensor alarm output

Alarm_OverTemp

std_logic

out

Over-Temperature alarm output

Alarm

std_logic

out

OR'ed output of all the Alarms

VP

std_logic

in

Dedicated Analog Input Pair

VN

std_logic

in